pyrex.askaryan.AskaryanSignal.em_shower_RAC¶
-
static
AskaryanSignal.
em_shower_RAC
(time, energy)¶ Calculates R*A_C at the given time and energy.
The R*A_C value is the observation distance R (m) times the vector potential (V*s/m) at the Cherenkov angle. This function calculates the R*A_C values for an electromagnetic shower.
- Parameters
- timearray_like
Time (s) at which to calculate the R*A_C value.
- energyfloat
Energy (GeV) of the shower.
- Returns
- array_like
The R*A_C value (V*s) at the given time.
See also
pyrex.ARZAskaryanSignal.had_shower_RAC
Calculates R*A_C at the given time and energy.
Notes
Based on equation 16 of the ARZ paper [1]. This parameterization is only described for electromagnetic showers in the paper. For the hadronic shower parameterization see the equivalent hadronic function.
References
- 1
J. Alvarez-Muniz et al, “Practical and accurate calculations of Askaryan radiation.” Physical Review D 84, 103003 (2011). arXiv:1106.6283 DOI:10.1103/PhysRevD.84.103003